BLINK-1
Carrier · 58STA090-1-16 90,000 BTU 80% AFUE Single-Stage Gas Furnace
The furnace control board LED flashes 1 time, pauses, then repeats. This indicates the furnace has tried and failed to ignite or sense flame too many times and has entered a safety lockout. The system will not attempt another ignition cycle until manually reset. To reset: turn the thermostat to OFF for 30 seconds, then back to HEAT; or cycle the furnace power switch off and on. If the furnace locks out again after reset, there is an underlying problem — most commonly a dirty flame sensor rod (clean with fine emery cloth or steel wool), a failed hot surface ignitor, no gas supply (check that the manual gas shutoff valve is open and other gas appliances work), or a faulty gas valve. The 1-blink lockout code means the furnace already tried multiple ignition attempts (typically 3) and failed each time before locking out.
Error BLINK-1 on the Carrier 58STA090-1-16 90,000 BTU 80% AFUE Single-Stage Gas Furnace means: LED 1 Blink — System Lockout (Retries Exceeded). The top-ranked community fix is “Test and Replace Hot Surface Ignitor or Gas Valve” (medium difficulty, ~60 min, DIY cost: $50-$100). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $250-$400.
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 4 Blinks — Open High-Limit Switch (Overheating)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded
LED 7 Blinks — Gas Valve Circuit Failure
LED 8 Blinks — Ignitor Circuit Fault / Low Flame Signal
LED 9 Blinks — Check Grounding / Reversed Polarity
The Carrier 58STA090-1-16 90,000 BTU 80% AFUE Single-Stage Gas Furnace has 8 other known error codes:
Error code BLINK-1 also appears on 3 other Carrier models: