BLINK-6
Carrier · Carrier 58SB0 Comfort 80 Single-Stage 80% AFUE Gas Furnace
The furnace control board LED flashes 6 times, pauses, then repeats. The furnace has detected that the 115V AC power supply has the hot and neutral wires reversed, or that the neutral wire is not properly bonded to ground. Carrier furnaces require correct electrical polarity for the flame sensing circuit to function — the flame sensor works by conducting a tiny DC current through the flame to the grounded burner assembly. If polarity is reversed, this circuit cannot work, and the furnace will fail to prove flame. To check: use a multimeter to verify that the narrow slot of the outlet (hot) reads ~120V to ground, and the wide slot (neutral) reads near 0V to ground. If reversed, the outlet wiring must be corrected by an electrician. If the furnace is hard-wired, check the junction box connections. Also verify that the grounding wire is properly connected. An older home with ungrounded outlets or incorrect wiring can cause this code.
Error BLINK-6 on the Carrier Carrier 58SB0 Comfort 80 Single-Stage 80% AFUE Gas Furnace means: LED 6 Blinks — 115V Power Reversed or Neutral Not Grounded. The top-ranked community fix is “Verify and Correct Furnace Power Wiring and Grounding” (medium difficulty, ~60 min, DIY cost: $0-$10). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · furnace
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many furnace repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $120-$250.
LED 1 Blink — System Lockout (Retries Exceeded)
LED 2 Blinks — Pressure Switch Stuck Closed
LED 3 Blinks — Pressure Switch Did Not Close (Draft Safeguard)
LED 4 Blinks — Open High-Limit Switch (Overheating)
LED 5 Blinks — Flame Sensed Without Gas Valve Call (Dangerous)
LED 7 Blinks — Gas Valve Circuit Failure
LED 8 Blinks — Ignitor Circuit Fault / Low Flame Signal
LED 9 Blinks — Check Grounding / Reversed Polarity
The Carrier Carrier 58SB0 Comfort 80 Single-Stage 80% AFUE Gas Furnace has 8 other known error codes: