MECH-PRESSURE-SWITCH
Bradford White · RG2PV40T6N 40 Gallon 40,000 BTU Power Vent Gas Water Heater with Defender Safety System
The pressure switch on the power vent system is not closing to prove draft, preventing the gas valve from firing. The pressure switch is a safety device that confirms the blower motor has created sufficient negative pressure (draft) to safely vent combustion gases. Check the rubber tubing connecting the pressure switch to the blower housing — it may be cracked, kinked, or disconnected. Verify the blower is actually running at full speed. Check the vent piping for blockages (ice, bird nests, debris). The condensate drain on the vent system must be clear — a clogged drain can cause water to block the vent and trip the pressure switch. If the tubing and vent are clear and the blower runs, replace the pressure switch.
Error MECH-PRESSURE-SWITCH on the Bradford White RG2PV40T6N 40 Gallon 40,000 BTU Power Vent Gas Water Heater with Defender Safety System means: Pressure Switch Failure — Won't Ignite. The top-ranked community fix is “Replace the Pressure Switch Assembly” (hard difficulty, ~60 min, DIY cost: $10-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $200-$300.
Normal Operation — System OK
Thermopile Voltage Low
High Temperature / ECO Trip
Temperature Sensor Failure
Gas Control Valve Electronics Failure
Power Interruption / Loss of Pilot Signal
No Power to Gas Control — LED Dark
Anode Rod Depleted — Rotten Egg Smell or Corrosion
The Bradford White RG2PV40T6N 40 Gallon 40,000 BTU Power Vent Gas Water Heater with Defender Safety System has 8 other known error codes:
Error code MECH-PRESSURE-SWITCH also appears on 1 other Bradford White model: