E10
Bosch · B36CT80SNS 36 in 800 Series French Door Counter Depth
The ambient (room) temperature sensor is reading out of range. This sensor adjusts compressor run time and defrost frequency based on the room temperature around the refrigerator. Check sensor location — usually on the main control board or near the fresh food compartment air inlet. Replace if defective. An incorrect ambient reading can cause over-cooling, insufficient cooling, or improper defrost scheduling.
Error E10 on the Bosch B36CT80SNS 36 in 800 Series French Door Counter Depth means: Ambient Temperature Sensor Error. The top-ranked community fix is “Test and Replace Ambient Temperature Sensor on Control Board” (medium difficulty, ~40 min, DIY cost: $20-$30). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · refrigerator
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many refrigerator repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $130-$200.
refrigerator · 2 fixes
refrigerator · 2 fixes
refrigerator · 2 fixes
refrigerator · 2 fixes
refrigerator · 2 fixes
refrigerator · 2 fixes
refrigerator · 2 fixes
Refrigerator Compartment Sensor Failure
Defrost Heater Failure
Compressor Overload — Repeated
Freezer Compartment Sensor Failure
Defrost Sensor / Bi-Metal Failure
Compressor Start Failure
Communication Error — Boards
Evaporator Fan Motor Failure
The Bosch B36CT80SNS 36 in 800 Series French Door Counter Depth has 8 other known error codes: