5 Flashes
A.O. Smith · GPVL-50 ProLine XE 50 Gal 38,000 BTU ProLine XE Power Vent Gas Water Heater
The temperature sensor (thermistor) has failed — it is reading open circuit or short circuit. The gas control valve cannot accurately monitor water temperature without a functioning sensor. The temperature sensor is typically integrated into the gas control valve on newer models. Check the sensor wire connections. If the sensor is a separate component, measure its resistance — it should change proportionally with temperature (typically 10K-50K ohms at room temperature). Replace the sensor or gas control valve as needed.
Error 5 Flashes on the A.O. Smith GPVL-50 ProLine XE 50 Gal 38,000 BTU ProLine XE Power Vent Gas Water Heater means: Temperature Sensor Failure. The top-ranked community fix is “Test and Replace Temperature Sensor or Gas Control Valve” (medium difficulty, ~45 min, DIY cost: $10-$20). 2 community-ranked fixes available below.
Published February 2026 · 2 fixes · water heater
Content is based on manufacturer service documentation, community repair experience, and OEM technical bulletins. Always verify with your owner's manual.Learn about our editorial standards.
While many water heater repairs can be done safely at home, consider hiring a qualified technician if:
Average professional repair cost for this issue: $250-$400.
water_heater · 2 fixes
water_heater · 2 fixes
water_heater · 2 fixes
The A.O. Smith GPVL-50 ProLine XE 50 Gal 38,000 BTU ProLine XE Power Vent Gas Water Heater has 5 other known error codes:
Error code 5 Flashes also appears on 3 other A.O. Smith models: